Loading...
HomeMy Public PortalAboutPublic Hearing - Zoning Amendment Bylaw - 1380.20 ____________________________________________________________ TOWN OF OLIVER Public Hearing Meeting Agenda February 14, 2022, following the Public Hearing for Zoning Amendment Bylaw 1380.23 Hybrid via Zoom Page A. CALL TO ORDER B. STATEMENT OF THE CHAIR C. BYLAWS 1. Zoning Amendment Bylaw 1380.20, Development Permit - 491 Salamander Avenue - Director of Development Services report attached Zoning Amendment, Development Permit (with variances) - 491 Salamander Avenue 2 - 32 D. ADJOURNMENT REGULAR OPEN COUNCIL REPORT Development Services Department For the February 14, 2022 Council Meeting DATE: February 14, 2022 File No. RZ 2021- 29, DP 2021-30 TO: Mayor and Council FROM: Randy Houle, Director of Development Services RE: Zoning Amendment, Development Permit - 491 Salamander Avenue RATIONALE: This application is seeking a zoning amendment from RM1 (Residential Medium Density One) to RM2 (Residential Medium Density Two) at 491 Salamander Avenue, legally known as Lot 337, District Lot 2450s, SDYD, Plan 1861, Except Plans 7995 and 11750, in order to construct a six - unit townhouse development comprising of two (3-unit) buildings. The applicant is also seeking a Multiple Family Development Permit and thus requires approval for the design and to address landscaping requirements. OPTIONS: 1. Council may choose to support the recommendation. 2. Council may choose not to support the recommendation. 3. Council may choose to refer back to staff for additional information. RECOMMENDATION: That Zoning Amendment Bylaw 1380.20 be read a third time; and That Zoning Amendment Bylaw 1380.20 be forwarded to the Ministry of Transportation for approval prior to adoption; and That Council consider Development Permit 2021-30 following the adoption of Zoning Amendment Bylaw 1380.20. ITEM C. - 1. Page 2 of 32 General: Organizational: Financial: Development Cost Charges will be applicable at the building permit stage, at a total cost of $9,245 per unit for a total of $55,470.00 Legal/Statutory Authority: Strategic Plan: Good Governance BACKGROUND: Site Context: The subject property is zoned RM1 (Residential Medium Density One) and is designated by the Official Community Plan as HR (High Density Residential). The property is approximately 1,254m2 (13,503ft2) in size with an older single family to b e demolished. The property is located in close proximity to the Community Centre, in an area with a mix of single family, multi family and institutional uses. Given the close proximity of the subject property to the downtown and several amenities, it has been identified as an area for increased density. Proposal: The applicant is proposing to construct a six-unit townhouse development on the subject property comprising of two separate (3-unit) buildings. Each unit features a carport and living space on the main floor with two bedrooms and a den on the second floor. Vehicle access to the site will be from the existing driveway on Salamander Avenue, with a new proposed exit at the southeast corner of the property onto Park Drive. This will result in a safer entry and exit for both vehicles and pedestrians. The maximum number of units permitted under the RM1 zone is six, with the maximum floor area ratio being 0.45 which equates to a maximum of 6,076ft2 of total floor space. In this case, the developer is proposing to construct six units that are 1,339ft2 each in size, for a total of 8,034ft2 of floor space which equates to 0.59 in floor area ratio. Given that the floor area ratio proposed exceeds the maximum allowed under the RM1 zone, a rezoning to RM2 (Residential Medium Density Two) is required which allows a maximum of 0.6. ITEM C. - 1. Page 3 of 32 Furthermore, the subject property is located within the Multiple Family Development Permit Area of the OCP and requires approval for the design and to address landscaping requirements. Regulatory Provisions: The OCP supports the use of lands designated High Density Residential (HR) identified in Schedule ‘B’ (Official Community Plan Map) for townhouses and apartment buildings, accessory structures, parks and neighbourhood commercial uses. The HR policies establish a minimum net density of 40 units per hectare and a maximum net density of 80 units per hectare. The proposed townhouse development is comprised of six-units which equates to 48 units per hectare and thus is aligned with this designation. Development Statistics: The following table outlines the proposed development statistics on the plans submitted with the application: Item RM2 zone Proposed Minimum Setbacks: front parcel line (east, Park Dr): rear parcel line (west) interior parcel line (south): exterior parcel line (north): 4.5m 6.0m 2.4m 4.0m 4.5m 6.0m 6.6m 4.0m Maximum Lot Coverage 40% 35% Maximum Floor Area 0.6 FAR 0.59 FAR Maximum Density 6 units 6 units Maximum Height 14.0m 7.6m Minimum Parking Spaces 6 + 1 visitor 6 + 2 visitor Minimum Loading Spaces 0 0 Minimum Amenity Space 40m2 per unit 47.5m2 per unit Analysis: Zoning Amendment Support Zoning Amendment Bylaw 1380.20 Staff considers the zoning amendment to allow for the proposed development represents best use of the land for the following reasons: ITEM C. - 1. Page 4 of 32 • Enabling a 0.60 floor area ratio rather than the 0.45 currently permitted in the RM1 zone allows for larger and more livable units for families. This results in an increase in 326ft2 per unit. • The maximum number of permitted units (50 dwelling units per hectares) will remain unchanged, therefore no additional traffic impacts are anticipated with the rezoning application. • The proposal is consistent with the growth management objectives of the Official Community Plan that support efficient use of land within the Town, including the infilling of vacant lots and supporting medium and higher density development in residential areas designated for such development. • The residential policies of the OCP speaks to prioritizing residential growth and infill within the Town's boundaries over the extension of boundaries. • The proposal will add 6 family-orientated units in close proximity to schools and other services, which also encourages more walking and active forms of transportation. The Housing Needs Report completed in 2020 indicates that in order to meet basic housing demand by 2025, 75 two-bedroom units are required which is broken down into 26 owner and 49 rental. The proposed construction will make a significant contribution towards this requirement, with the tenure of the units being unknown at this time. Deny Zoning Amendment Bylaw 1380.20 Council may consider that the increase in floor area ratio will be a detriment to the area and neighbouring properties. If this the case, Council should choose not to support the staff recommendation. Development Permit ITEM C. - 1. Page 5 of 32 Support Development Permit 2021-30 The subject property is located within the Multiple Family Development Permit Area. The objectives of this designation are to ensure that the siting, form, character and landscaping of new multiple family development are compatible with the surrounding neighbourhood. This includes the overall aesthetic quality of the development as well as site plan elements including access, parking, storage and landscaping. The proposed development meets the intent of the Multiple Family DP Area as highlighted below: • The front façade features multi material types such as horizontal hardi and board and batten with a mix of grey and white colour. • Each unit facing Salamander Avenue has two individual roof peaks rather than a uniform box look, thus adding visual interest to the building. The end unit facing Park Drive includes an entry and pedestrian walkway to the sidewalk, along with the existing multiple windows and a roof peak, which minimizes the blank look appearance that the side of a building can pose. • The Park Drive frontage will be landscaped with multiple trees, grass and boxwood hedge, improving the aesthetic value of the development. • The Salamander frontage will feature a 4ft high wood fence with individual pedestrian walkways to the units, thus providing a pleasant connection to the street. Each unit will have a small private outdoor amenity space. • Garbage and recycling areas will be located at the south west corner of the development, screened from view of the street. Deny Development Permit 2021-30 Council may consider that the form and character should be revised or more landscaping added. If this is the case, Council should deny the permit following the adoption of the zoning amendment bylaw. REFERRALS: Approval from the Ministry of Transportation and Infrastructure (MoTI) is required prior to adoption of Zoning Amendment Bylaw 1380.20 as the proposed amendment will apply to lands within 800 metres of a “controlled area” (i.e. Highway 97). MOTI has granted preliminary approval of the rezoning for a period of one year. The application was referred to various internal and external departments with several items to be addressed at the building permit stage. This includes the requirement for on -site civil drawings which will address all servicing components, such as water and sewer upgrades. ITEM C. - 1. Page 6 of 32 PUBLIC PROCESS: Notice of the February 14, 2022 Public Hearing was mailed to residents within 100.0m of the subject property. A public notification sign was installed on the subject property and notice of the public hearing was advertised in two editions of the local print newspaper. COUNCIL REPORT/RESOLUTION HISTORY: At the January 24th, 2022 Regular Open Council Meeting, the following resolution was passed by Council: R-23/2022 It was MOVED and SECONDED That Zoning Amendment Bylaw 1380.20 be read a first and second time and proceed to a Public Hearing; and That the holding of the Public Hearing be scheduled for February 14, 2022; and That Staff give notice of the Public Hearing in accordance with the requirements of the Local Government Act; and That Council consider Development Permit 2021-30 following the adoption of Zoning Amendment Bylaw 1380.20. CARRIED At the January 10th, 2022 Regular Open Council Meeting, the following resolution was pass ed by Council: R-09/2022 It was MOVED and SECONDED That Council refers Zoning Amendment Bylaw 1380.20 and Development Permit (with variances) for 491 Salamander Avenue back to staff for additional information. CARRIED Respectfully Submitted: ITEM C. - 1. Page 7 of 32 ______________________________________ Randy Houle Director of Development Services Approved By: Department: Status: Ed Chow, Chief Administrative Officer Approved - 25 Jan 2022 Attachments: attachments 2022-01-18 Revised Plans 2022-01-18 - Revised Letter of Intent 1380.20 Zoning Amendment Bylaw (491 Salamander Ave) DP 2021-30 ITEM C. - 1. Page 8 of 32 Figure 1: Property Location Map ITEM C. - 1. Page 9 of 32 Figure 2: Ortho Map ITEM C. - 1. Page 10 of 32 Figure 3: OCP Map Figure 4: Zoning Map ITEM C. - 1. Page 11 of 32 Figure 5: Park Drive Elevation of Subject Property Figure 6: Park Drive Elevation of Subject Property ITEM C. - 1. Page 12 of 32 Figure 7: Salamander Ave Elevation of Subject Property Figure 8: South Portion of Subject Property ITEM C. - 1. Page 13 of 32 20.012 date:project number:drawing title: drawing number:Development Permitissued for: project name:norm erxleben 604.763.7517 building technologist 112-1115 holden rd. penticton bc canada v2a 0b7 norm.erxleben@gmail.com 2 - 4 Plex Development 491 Salamander Avenue, Oliver, BC technology + design 2022.01.17 a000 n/aCover Sheet scale: 4 9 1 S a l a m a n d e r A v e n u e D e v e l o p m e n t O l i v e r , B C R e - S u b m i t t e d f o r D e v e l o p m e n t P e r m i t - 2 0 2 2 . 0 1 . 1 7 a000.................................................................. a001.............................................................. a002............................................................ a003.......................................................................... a004.................................................. a005............................................... a006....................................................................... a007................................................... a008............................................... a009...................................................................... a010..................................................................... a011.................................................................... a012................................................................... COVER SHEET SITE STATISTICS LANDSCAPE PLAN SITE PLAN MAIN FLOOR SITE PLAN UPPER FLOOR SITE PLAN ROOF PLAN COMPLEX MAIN FLOOR COMPLEX UPPER FLOOR ELEVATION I ELEVATION II ELEVATION III ELEVATION IV DRAWING LIST: IT E M C . - 1 . Pa g e 1 4 o f 3 2 SALAMANDER AVENUE PA R K D R I V E 7' - 1 0 1 / 2 " EXT. SETBACK FR O N T S E T B A C K RE A R S E T B A C K 14'-9"19'-7 1/4" ONE WAY DRIVE AISLE 21 ' - 9 1 / 4 " 4.5m6.0m 2. 4 m INT. SETBACK 6. 6 m ENTER ONLY EXIT ONLY 59' 17.9m 19' 5.8m 59' 17.9m 13 ' - 1 1 / 2 " 4. 0 m 40 ' - 6 " 12 . 3 m COMPLEX 1 BLDG FOOTPRINT 2,370.4 sf COMPLEX 2 BLDG FOOTPRINT 2,370.4 sf SALAMANDER AVENUE PA R K D R I V E 7' - 1 0 1 / 2 " EXT. SETBACK FR O N T S E T B A C K RE A R S E T B A C K 14'-9"19'-7 1/4" ONE WAY DRIVE AISLE 21 ' - 9 1 / 4 " 4.5m6.0m 2. 4 m INT. SETBACK 13 ' - 1 1 / 2 " 4. 0 m 6. 6 m ENTER ONLY EXIT ONLY 59'19' 5.8m 59' 17.9m COMPLEX 1 BLDG FOOTPRINT 2,370.4 sf COMPLEX 2 BLDG FOOTPRINT 2,370.4 sf 40 ' - 6 " 12 . 3 m 17.9m 20.012 date:project number:drawing title: drawing number:Development Permitissued for: project name:norm erxleben 604.763.7517 building technologist 112-1115 holden rd. penticton bc canada v2a 0b7 norm.erxleben@gmail.com 2 - 4 Plex Development 491 Salamander Avenue, Oliver, BC technology + design 2022.01.17 a001 n/aZoning Stat Sheet scale: ZONING BYLAW SUMMARY: CIVIC ADDRESSES:491 SALAMANDER AVENUE, OLIVER, BC. LEGAL DESCRIPTION: LOT AREA - ALLOWED:RH1 allows 50 dwellings per hectare (107,639 sf) 13,503 sf this allows 6 dwelling units on the property with a FAR (floor area ratio) of 0.6 (0.6 x 13,503 = 8,101.8 sf gross building area) Each complex sf building footprint is 2,370.4 x 2 = 4,740.8 sf total. ZONING:EXISTING 'RM1' PROPOSED 'RM2' MEDIUM DENSITY RESIDENTIAL TWO Lot 337, Plan KAP1861, District Lot 2450S, Similkameen Div of Yale Land District, Except Plan 7995, & EXC PL 11750 MAXIMUM HEIGHT:14 m [45'-9"] - PROPOSED 7.6m MINIMUM RESIDENTIAL SETBACKS: FRONT SIDE (INTERIOR) 4.5 m [14.76 ft] SIDE (EXTERIOR) 2.4 m [7.87 ft ] BYLAW:ZONING BYLAW 1380 REAR 4.0 m [13.10 ft] 6.0 m [19.68 ft] SITE COVERAGE:PROPOSED 35% (4,740.6 / 13,503) UNIT AREAS - SINGLE UNIT:LOWER FLOOR 549.8 sf UPPER FLOOR 790.1 sf TOTAL 1,339.9 sf BUILDING AREA:790.1 sf x 6 units = 4,740.6 sf PARKING:1 PER DWELLING UNIT - 6 TOTAL PLUS 1 VISITOR (0.2 x 6 = 1.2) Provided 6 units stalls plus 2 visitor TOTAL BUILDING AREA:8,039.4sf (6 units x 1,339.9 sf = .59 F.A.R.) MAXIMUM DENSITY:50 DWELLINGS PER HECTARE LOT AREA:13,503 sf TOTAL BUILDING FOOTPRINT:4,740.6 sf (6 units @ 790.1 sf) PROPOSED BUILDING FOOTPRINT 4,740.8sf Scale: ALLOWABLE AREA 1/32"=1'-0" 01 - REQUIRED AMENITY SPACE 6 UNITS x 40m2 =240m2 (2,583.3sf) - PROVIDED AMENITY SPACE = 285.0m2 (3,068.0sf) OR 47.5m2 PER UNIT Scale: AMENITY SPACE 1/32"=1'-0" 02 - Scale: GIS PLAN N.T.S. 03 - IT E M C . - 1 . Pa g e 1 5 o f 3 2 SALAMANDER AVENUE PA R K D R I V E 7' - 1 0 1 / 2 " FR O N T S E T B A C K 14'-9"19'-7 1/4" ONE WAY DRIVE AISLE 21 ' - 9 1 / 4 " 4.5m6.0m 2. 4 m INT. SETBACK 6. 6 m 11 23 4 6 7 8 6 2 3 49 5 2 5 6 7 8 9 9 9 10 RE A R S E T B A C K ENTER ONLY EXIT ONLY 11 1212 LINE OF FLOOR OVERLINE OF FLOOR OVER 40 ' - 6 " 12 . 3 m 13 ' - 1 1 / 2 " 4. 0 m 59'19' 5.8m 59' 17.9m17.9m 11 Unit 1 Unit 2 Unit 3 Unit 5 Unit 6Unit 4 Carports Unit 4 Unit 5 Unit 6Unit 1 Unit 2 Unit 3 Visitor 1 Visitor 2 20.012 date:project number:drawing title: drawing number:Development Permitissued for: project name:norm erxleben 604.763.7517 building technologist 112-1115 holden rd. penticton bc canada v2a 0b7 norm.erxleben@gmail.com 2 - 4 Plex Development 491 Salamander Avenue, Oliver, BC technology + design 2022.01.17 a002 n/aLandscape Plan scale: PLANTING LIST:Scale: LANDSCAPE PLAN 1/16"=1'-0" 01 - 1 ARBORUITAE 3 - 4 PER PLANTER x 7 UNITS = 21 - 28 TOTAL COUNT 2 3 LAWN: INTERIOR BLUEGRASS, DROUGHT RESISTANT SOD c/w IRRIGATION SYSTEM GREEN ASH, FRAXINUS PENNSYLVATICUM - TOTAL COUNT 01 4 TRIDENT MAPLE, ACER CAMPESTRE - TOTAL COUNT 01 5 6 BOXWOOD HEDGE, BUXUS TOTAL COUNT APPROXIMATELY 25 COLUMNAR GIGNKO, GINGKO BILOBA ' FASTIGATA' - TOTAL COUNT 02 7 RED MAPLE, ACER RUBRUM - TOTAL COUNT 01 8 COLUMNAR OAK, QUERCUS ROBUR 'FASTIAGIATA - TOTAL COUNT 01 1 ONE WAY ASPHALT ENTRY DRIVEAILSE c/w SIGNAGE - REFER TO CITY STANDARDS 2 BRUSHED CONCRETE ENTRY WALKWAY 3 RAISED TREATED WOOD DRIP THROUGH DECK 4 3'-6" HIGH HORIZONTAL WOOD SLAT FENCE 5 AREA DRAIN(S) 6 PROPOSED TRANSFORMER LOCATION - ON CONCRETE PAD c/w CRUSHED GRAVEL SURROUND 7 RECYCLING - CRUSHED ROCK SURROUND 8 GARBAGE - ON ASPHALT PAD c/w CRUSHED GRAVEL SURROUND 9 WEST AND SOUTH SIDE PERIMETER 6'-0" HIGH WOOD SCREEN FENCE AT PROPERTY LINE SITE MATERIALS: 10 ONE WAY ASPHALT EXIT DRIVEAILSE c/w SIGNAGE - REFER TO CITY STANDARDS 9 XERISCAPE STYLE PLANTING c/w DROUGHT RESISTANT PLANTS AND DRIP LINE IRRIGATION 11 ELECTRICAL METER LOCATION 12 2 x GARAGE SEE-THRU SCREENING IT E M C . - 1 . Pa g e 1 6 o f 3 2 SALAMANDER AVENUE PA R K D R I V E 7' - 1 0 1 / 2 " FR O N T S E T B A C K RE A R S E T B A C K 14'-9"19'-7 1/4" ONE WAY DRIVE AISLE 21 ' - 9 1 / 4 " 4.5m6.0m 2. 4 m INT. SETBACK 6. 6 m GARBAGE/ RECYCLING/ TRANSFORMER 72'-5 1/4" 22.0m 10'-3" 3.1m 54'-3 3/4" 16.53m 40 ' - 6 " 12 . 3 m ENTER ONLY EXIT ONLY 13 ' - 1 1 / 2 " 4. 0 m 20.012 date:project number:drawing title: drawing number:Development Permitissued for: project name:norm erxleben 604.763.7517 building technologist 112-1115 holden rd. penticton bc canada v2a 0b7 norm.erxleben@gmail.com 2 - 4 Plex Development 491 Salamander Avenue, Oliver, BC technology + design 2022.01.17 a003 1/16"=1'-0"Proposed Overall Site Plan scale: Scale: SITE PLAN 1/16"=1'-0" 01 - IT E M C . - 1 . Pa g e 1 7 o f 3 2 SALAMANDER AVENUE PA R K D R I V E 7' - 1 0 1 / 2 " FR O N T S E T B A C K RE A R S E T B A C K ONE WAY DRIVE AISLE 21 ' - 9 1 / 4 " GARBAGE/ RECYCLING/ TRANSFORMER 2. 4 m INT. SETBACK 6. 6 m Carports ENTER ONLY EXIT ONLY EXT. SETBACK UP L I V I N GD I N I N G K I T C H E N B A T H E N T R Y C O A T S E N T R Y 9'-9" x 10'-8"9'-2" x 9'-0" 15'-7" x 10'-9" 3'-8" x 7'-7" S T O R. / U T I L. 8'-7" x 4'-1" P A R K I N G 10'-6" x 18'-0" UP L I V I N G D I N I N G K I T C H E N B A T H E N T R Y C O A T S 9'-9" x 10'-8" 9'-2" x 9'-0" 15'-7" x 10'-9" 3'-8" x 7'-7" S T O R. / U T I L. 8'-7" x 4'-1" P A R K I N G 10'-6" x 18'-0" LINE OF FLOOR OVER Unit 4 Unit 5 Unit 6 UP L I V I N GD I N I N G K I T C H E N B A T H E N T R Y C O A T S E N T R Y 9'-9" x 10'-8"9'-2" x 9'-0" 15'-7" x 10'-9" 3'-8" x 7'-7" S T O R. / U T I L. 8'-7" x 4'-1" P A R K I N G 10'-6" x 18'-0" UP L I V I N GD I N I N G K I T C H E N B A T H E N T R Y C O A T S E N T R Y 9'-9" x 10'-8"9'-2" x 9'-0" 15'-7" x 10'-9" 3'-8" x 7'-7" S T O R. / U T I L. 8'-7" x 4'-1" P A R K I N G 10'-6" x 18'-0" LINE OF FLOOR OVER Unit 1 Unit 2 Unit 3 UP L I V I N GD I N I N G K I T C H E N B A T H E N T R Y C O A T S E N T R Y 9'-9" x 10'-8"9'-2" x 9'-0" 15'-7" x 10'-9" 3'-8" x 7'-7" S T O R. / U T I L. 8'-7" x 4'-1" P A R K I N G 10'-6" x 18'-0" 14'-9"19'-7 1/4" 4.5m6.0m 59' 17.9m 19' 5.8m 59' 17.9m 13 ' - 1 1 / 2 " 4. 0 m Visitor 1 Visitor 2 UP L I V I N GD I N I N G K I T C H E N B A T H E N T R Y C O A T S E N T R Y 9'-9" x 10'-8"9'-2" x 9'-0" 15'-7" x 10'-9" 3'-8" x 7'-7" S T O R. / U T I L. 8'-7" x 4'-1" P A R K I N G 10'-6" x 18'-0" 40 ' - 6 " 12 . 3 m 20.012 date:project number:drawing title: drawing number:Development Permitissued for: project name:norm erxleben 604.763.7517 building technologist 112-1115 holden rd. penticton bc canada v2a 0b7 norm.erxleben@gmail.com 2 - 4 Plex Development 491 Salamander Avenue, Oliver, BC technology + design 2022.01.17 a004 1/16"=1'-0"Proposed Site Plan - Main scale: Scale: SITE PLAN 1/16"=1'-0" 01 - IT E M C . - 1 . Pa g e 1 8 o f 3 2 SALAMANDER AVENUE PA R K D R I V E 7' - 1 0 1 / 2 " FR O N T S E T B A C K RE A R S E T B A C K 14'-9"19'-7 1/4" ONE WAY DRIVE AISLE 21 ' - 9 1 / 4 " 4.5m6.0m 2. 4 m INT. SETBACK 6. 6 m GARBAGE/ RECYCLING/ TRANSFORMER ENTER ONLY EXIT ONLY EXT. SETBACK 59' 17.9m 19' 5.8m 59' 17.9m 13 ' - 1 1 / 2 " 4. 0 m E N S U I T E B A T H B E D R O O M D E N M A S T E R B E D R O O M DN 11'-5" x 5'-0" 11'-5" x 5'-0" 9'-6" x 16'-9" 9'-2 x 8'-0" 10'-10" x 16'-9" E N S U I T E B A T H B E D R O O M D E N M A S T E R B E D R O O M DN 11'-5" x 5'-0" 11'-5" x 5'-0" 9'-6" x 16'-9" 9'-2 x 8'-0" 10'-10" x 16'-9" DN E N S U I T E B A T H B E D R O O M D E N M A S T E R B E D R O O M 11'-0" x 5'-0" 11'-0" x 5'-0" 9'-6" x 16'-4" 8'-9" x 8'-0" 10'-10" x 16'-4" E N S U I T E B A T H B E D R O O M D E N M A S T E R B E D R O O M DN 11'-5" x 5'-0" 11'-5" x 5'-0" 9'-6" x 16'-9" 9'-2 x 8'-0" 10'-10" x 16'-9" E N S U I T E B A T H B E D R O O M D E N M A S T E R B E D R O O M DN 11'-5" x 5'-0" 11'-5" x 5'-0" 9'-6" x 16'-9" 9'-2 x 8'-0" 10'-10" x 16'-9" E N S U I T E B A T H B E D R O O M D E N M A S T E R B E D R O O M DN 11'-5" x 5'-0" 11'-5" x 5'-0" 9'-6" x 16'-9" 9'-2 x 8'-0" 10'-10" x 16'-9" 40 ' - 6 " 12 . 3 m 20.012 date:project number:drawing title: drawing number:Development Permitissued for: project name:norm erxleben 604.763.7517 building technologist 112-1115 holden rd. penticton bc canada v2a 0b7 norm.erxleben@gmail.com 2 - 4 Plex Development 491 Salamander Avenue, Oliver, BC technology + design 2022.01.17 a005 1/16"=1'-0"Proposed Site Plan - Upper scale: Scale: SITE PLAN 1/16"=1'-0" 01 - IT E M C . - 1 . Pa g e 1 9 o f 3 2 SALAMANDER AVENUE PA R K D R I V E 7' - 1 0 1 / 2 " FR O N T S E T B A C K RE A R S E T B A C K 14'-9"19'-7 1/4" ONE WAY DRIVE AISLE 21 ' - 9 1 / 4 " 4.5m6.0m 2. 4 m INT. SETBACK 6. 6 m GARBAGE/ RECYCLING/ TRANSFORMER 72'-5 1/4" 22.0m 10'-3" 3.1m 54'-3 3/4" 16.53m 40 ' - 6 " 12 . 3 m ENTER ONLY EXIT ONLY 13 ' - 1 1 / 2 " 4. 0 m 20.012 date:project number:drawing title: drawing number:Development Permitissued for: project name:norm erxleben 604.763.7517 building technologist 112-1115 holden rd. penticton bc canada v2a 0b7 norm.erxleben@gmail.com 2 - 4 Plex Development 491 Salamander Avenue, Oliver, BC technology + design 2022.01.17 a006 1/16"=1'-0"Proposed Roof Plan scale: Scale: SITE PLAN 1/16"=1'-0" 01 - IT E M C . - 1 . Pa g e 2 0 o f 3 2 UP L I V I N GD I N I N G K I T C H E N B A T H E N T R Y C O A T S E N T R Y 9'-9" x 10'-8"9'-2" x 9'-0" 15'-7" x 10'-9" 3'-8" x 7'-7" S T O R. / U T I L. 8'-7" x 4'-1" P A R K I N G 10'-6" x 18'-0" UP L I V I N G D I N I N G K I T C H E N B A T H E N T R Y C O A T S 9'-9" x 10'-8" 9'-2" x 9'-0" 15'-7" x 10'-9" 3'-8" x 7'-7" S T O R. / U T I L. 8'-7" x 4'-1" P A R K I N G 10'-6" x 18'-0" LINE OF FLOOR OVER Unit 4 Unit 5 Unit 6 22 ' - 6 1 / 2 " UP L I V I N GD I N I N G K I T C H E N B A T H E N T R Y C O A T S E N T R Y 9'-9" x 10'-8"9'-2" x 9'-0" 15'-7" x 10'-9" 3'-8" x 7'-7" S T O R. / U T I L. 8'-7" x 4'-1" P A R K I N G 10'-6" x 18'-0" 12 ' - 6 " 5' - 6 1 / 2 " 1' - 0 " 34 ' - 1 " 5' - 7 " 19'-8"19'-8"19'-8" 10'-6"9'-2"10'-6"9'-2"10'-6"9'-2" 59'-0" 59'-1" MAIN - 549.8sf 20.012 date:project number:drawing title: drawing number:Development Permitissued for: project name:norm erxleben 604.763.7517 building technologist 112-1115 holden rd. penticton bc canada v2a 0b7 norm.erxleben@gmail.com 2 - 4 Plex Development 491 Salamander Avenue, Oliver, BC technology + design 2022.01.17 a007 3/16"=1'-0"Main Floor Complex 2 scale: Scale: MAIN FLOOR 3/16"=1'-0" 01 - IT E M C . - 1 . Pa g e 2 1 o f 3 2 DN E N S U I T E B A T H B E D R O O M D E N M A S T E R B E D R O O M 11'-0" x 5'-0" 11'-0" x 5'-0" 9'-6" x 16'-4" 8'-9" x 8'-0" 10'-10" x 16'-4" E N S U I T E B A T H B E D R O O M D E N M A S T E R B E D R O O M DN 11'-5" x 5'-0" 11'-5" x 5'-0" 9'-6" x 16'-9" 9'-2 x 8'-0" 10'-10" x 16'-9" E N S U I T E B A T H B E D R O O M D E N M A S T E R B E D R O O M DN 11'-5" x 5'-0" 11'-5" x 5'-0" 9'-6" x 16'-9" 9'-2 x 8'-0" 10'-10" x 16'-9" 40 ' - 7 " 1' - 0 " 34 ' - 1 " 5' - 7 " 19'-8"19'-8"19'-8" 19'-8" 59'-0" 59'-1" 19'-8"19'-8" UPPER - 790.1sf 20.012 date:project number:drawing title: drawing number:Development Permitissued for: project name:norm erxleben 604.763.7517 building technologist 112-1115 holden rd. penticton bc canada v2a 0b7 norm.erxleben@gmail.com 2 - 4 Plex Development 491 Salamander Avenue, Oliver, BC technology + design 2022.01.17 a008 1/16"=1'-0"Upper Floor scale: Scale: UPPER FLOOR 3/16"=1'-0" 01 - IT E M C . - 1 . Pa g e 2 2 o f 3 2 1 ASPHALT SHINGLES - CHARCOAL 2 HORIZONTAL CEMENTIOUS SIDING (HARDIBOARD) - WHITE 3 CEMENTITIOUS BOARD AND BATTEN (HARDIBOARD/PANEL) - GREY 4 VINYL WINDOWS - BLACK 5 VINYL SLIDING DOORS - BLACK 6 VISION PANE FRONT DOORS - FRAMES BLACK 7 CEMENTITIOUS TRIM BAND (HARDIBOARD) - GREY 9'-0"UPPER 8'-0"CEILING 0'- 0" MAIN FLOOR 9' - 0 " 1' - 0 " 9' - 0 " 25 ' - 3 " 25'-3" ROOF PEAK 18'-0" CEILING 6' - 3 " 1 2 43 5 6 7 8 2 x WOOD SCREEN 9 1'- 6" CANOPY PROJECTION 9 20.012 date:project number:drawing title: drawing number:Development Permitissued for: project name:norm erxleben 604.763.7517 building technologist 112-1115 holden rd. penticton bc canada v2a 0b7 norm.erxleben@gmail.com 2 - 4 Plex Development 491 Salamander Avenue, Oliver, BC technology + design 2022.01.17 a009 3/16"=1'-0"Salamader Elevation scale: Scale: ELEVATION 3/16"=1'-0" 01 - IT E M C . - 1 . Pa g e 2 3 o f 3 2 9'-0"UPPER 8'-0"CEILING 0'- 0" MAIN FLOOR 9' - 0 " 1' - 0 " 9' - 0 " 25 ' - 3 " 25'-3" ROOF PEAK 18'-0" CEILING 6' - 3 " 1 2 43 7 1 ASPHALT SHINGLES - CHARCOAL 2 HORIZONTAL CEMENTIOUS SIDING (HARDIBOARD) - WHITE 3 CEMENTITIOUS BOARD AND BATTEN (HARDIBOARD/PANEL) - GREY 4 VINYL WINDOWS - BLACK 5 VINYL SLIDING DOORS - BLACK 6 VISION PANE FRONT DOORS - FRAMES BLACK 7 CEMENTITIOUS TRIM BAND (HARDIBOARD) - GREY 8 2 x WOOD SCREEN 9 1'- 6" CANOPY PROJECTION 20.012 date:project number:drawing title: drawing number:Development Permitissued for: project name:norm erxleben 604.763.7517 building technologist 112-1115 holden rd. penticton bc canada v2a 0b7 norm.erxleben@gmail.com 2 - 4 Plex Development 491 Salamander Avenue, Oliver, BC technology + design 2022.01.17 a010 3/16"=1'-0"Rear Elevation scale: Scale: ELEVATION 3/16"=1'-0" 01 - IT E M C . - 1 . Pa g e 2 4 o f 3 2 9'-0"UPPER 8'-0"CEILING 0'- 0" MAIN FLOOR 9' - 0 " 1' - 0 " 9' - 0 " 25 ' - 3 " 25'-3" ROOF PEAK 18'-0" CEILING 6' - 3 " 1 2 4 743 8 1 ASPHALT SHINGLES - CHARCOAL 2 HORIZONTAL CEMENTIOUS SIDING (HARDIBOARD) - WHITE 3 CEMENTITIOUS BOARD AND BATTEN (HARDIBOARD/PANEL) - GREY 4 VINYL WINDOWS - BLACK 5 VINYL SLIDING DOORS - BLACK 6 VISION PANE FRONT DOORS - FRAMES BLACK 7 CEMENTITIOUS TRIM BAND (HARDIBOARD) - GREY 8 2 x WOOD SCREEN 20.012 date:project number:drawing title: drawing number:Development Permitissued for: project name:norm erxleben 604.763.7517 building technologist 112-1115 holden rd. penticton bc canada v2a 0b7 norm.erxleben@gmail.com 2 - 4 Plex Development 491 Salamander Avenue, Oliver, BC technology + design 2022.01.17 a011 3/16"=1'-0"Interior Side Elevation scale: Scale: ELEVATION 3/16"=1'-0" 01 - IT E M C . - 1 . Pa g e 2 5 o f 3 2 1 2 4 7 9'-0"UPPER 8'-0"CEILING 0'- 0" MAIN FLOOR 9' - 0 " 1' - 0 " 9' - 0 " 25 ' - 3 " 25'-3" ROOF PEAK 18'-0" CEILING 6' - 3 " 8 1 ASPHALT SHINGLES - CHARCOAL 2 HORIZONTAL CEMENTIOUS SIDING (HARDIBOARD) - WHITE 3 CEMENTITIOUS BOARD AND BATTEN (HARDIBOARD/PANEL) - GREY 4 VINYL WINDOWS - BLACK 5 VINYL SLIDING DOORS - BLACK 6 VISION PANE FRONT DOORS - FRAMES BLACK 7 CEMENTITIOUS TRIM BAND (HARDIBOARD) - GREY 8 2 x WOOD SCREEN 3 9 1'- 6" CANOPY PROJECTION 9 20.012 date:project number:drawing title: drawing number:Development Permitissued for: project name:norm erxleben 604.763.7517 building technologist 112-1115 holden rd. penticton bc canada v2a 0b7 norm.erxleben@gmail.com 2 - 4 Plex Development 491 Salamander Avenue, Oliver, BC technology + design 2022.01.17 a012 3/16"=1'-0"Exterior Side Elevation scale: Scale: ELEVATION 3/16"=1'-0" 01 - IT E M C . - 1 . Pa g e 2 6 o f 3 2 20.012 date:project number:drawing title: drawing number:Development Permitissued for: project name:norm erxleben 604.763.7517 building technologist 112-1115 holden rd. penticton bc canada v2a 0b7 norm.erxleben@gmail.com 2 - 4 Plex Development 491 Salamander Avenue, Oliver, BC technology + design 2022.01.17 a013 3/32"=1'-0"Street Elevations scale: Scale: ELEVATION 1/32"=1'-0" 01 - Scale: ELEVATION 1/32"=1'-0" 02 -Scale: ELEVATION 1/32"=1'-0" 03 - IT E M C . - 1 . Pa g e 2 7 o f 3 2 norm erxleben 604.763.7517 112 – 1115 holden street penticton, bc, v2a 0b7 norm.erxleben@gmail.com 112 – 1115 holden street, penticton, bc v2a 0b7 t: 604.763.7517 e: norm.erxleben@gmail.com 2022.01.18 Randy Houle | Director of Development Services Box 638 6150 Main Street, Oliver, BC. rhoule@oliver.ca 250.485.6206 RE: 491 Salamander Avenue Development Permit re-Submission Dear Sirs, We are pleased to present our revised proposed residential development to council for consideration. Based on Council’s previous comments we have reworked the project to reflect those items by reducing the total unit count to 6. With Planning’s recommendation to apply RM2 as the new zoning bylaw we are able to meet the required setbacks, amenity space and F.A.R areas and are not seeking any variances for this property. We have also included 2 visitor parking spots located centrally on the property. We hope the adjustments made to this development are seen favorably and demonstrate our commitment to provide conscientious housing to the Town of Oliver. Sincerely, ____________________________________________ Norm Erxleben | Senior Building Technologist norm.erxleben@gmail.com ITEM C. - 1. Page 28 of 32 TOWN OF OLIVER BYLAW 1380.20 A Bylaw to Amend Town of Oliver Zoning Bylaw 1380 The Council of the Town of Oliver, in open meeting assembled, ENACTS AS FOLLOWS: 1. This bylaw may be cited for all purposes as “Zoning Amendment Bylaw 1380.20.” 2. The Zoning Bylaw Map, being Schedule ‘B’ of the Town of Oliver Zoning Bylaw No. 1380 is amended by changing the land use designation of the parcel described as Lot 337, District Lot 2450s, SDYD, Plan 1861, Except Plans 7995 and 11750 and shown shaded yellow on Schedule ‘A’, which forms part of this Bylaw, from RM1 (Residential Medium Density One) to RM2 (Residential Medium Density Two). Read a first and second time on the 24 day of January, 2022. Public hearing held on the ___ day of ___________, 2022. Read a third time on the ___ day of ___________, 2022. Adopted on the ___ day of ___________, 2022. _______________________ ____________________________ Mayor Corporate Officer Approved pursuant to section 52(3)(a) of the Transportation Act this ___ day of _________, 2022 ITEM C. - 1. Page 29 of 32 Zoning Amendment Bylaw No. 1380.20 Page 2 Schedule ‘A’ NN Amend Zoning Bylaw 1380: from: RM1 (Residential Medium Density One) to: RM2 (Residential Medium Density Two) (YELLOW SHADED AREA) ITEM C. - 1. Page 30 of 32 Development Permit No. 2021-30 Page 1 of 2 Development Permit No. 2021-30 Owner: Name: Address: GENERAL CONDITIONS 1. This Development Permit is issued subject to compliance with all of the bylaws of the Town of Oliver applicable thereto, except as specifically varied or supplemented by this Permit. 2. The land described shall be developed strictly in accordance with the terms and conditions of this Permit, and any plans and specifications attached to this Permit which shall form a part thereof. 3. Where there is a conflict between the text of the permit and permit drawings or figures, the drawings or figures shall govern the matter. 4. This Development Permit is not a Building Permit. APPLICABILITY 5. This Development Permit applies to, and only to, those lands, including any and all buildings, structures and other development thereon, within the Town of Oliver as shown on Schedule A, and described below: Legal Description: Lot 337, District Lot 2450s, SDYD, Plan 1861, Except Plans 7995 and 11750 Civic Address/location: 491 Salamander Avenue Parcel Identifier (PID): 011-633-590 Folio: 00619.000 CONDITIONS OF DEVELOPMENT 6. In accordance with Section 23.4 of the Town of Oliver Official Community Plan Bylaw 1370, the land specified in Section 5 may be developed in accordance with the following conditions: a) THAT the proposed building is constructed and externally finished in accordance to the site plans and architectural drawing attached as Schedule A. ITEM C. - 1. Page 31 of 32 Development Permit No. 2021-30 Page 2 of 2 SECURITY REQUIREMENTS 7. Prior to the issuance of a Building Permit, and as a condition of this Development Permit, the Town of Oliver is holding the security set in the form of an “Irrevocable Letter of Credit” or cash deposit in the amount of 125% of the estimated value of the landscaping, as determined by a professional landscaper to ensure that development is carried out in accordance with the terms and conditions of this Permit and Schedule A. Conditions for returning the security are as follows: 100% returned after installation and inspection. Where the Owner fails to comply with all of the conditions and undertakings specified in this Permit, the Town of Oliver may enter on the land and carry out the demolition, removal or restoration at the expense of the Owner, and may apply the security in payment of the cost of the works, with the excess to be returned to the Owner. Should any interest be earned upon the security, it shall accrue to the Owner and be paid to the Owner if the security is returned. There is filed accordingly: i) an irrevocable Letter of Credit or cash deposit in the amount of: $25,000.00 EXPIRY OF PERMIT 8. The development shall be carried out according to the following schedule: (a) In accordance with Section 504 of the Local Government Act and subject to the terms of the permit, if the holder of this permit does not substantially start any construction with respect to which the permit was issued within two (2) years after the date it was issued, the permit lapses. (b) Lapsed permits cannot be renewed; however, an application for a new development permit can be submitted. Authorizing resolution passed by the Council of the Town of Oliver on the __ day of ___________, 2022. ____________________ Corporate Officer Issued: the ___ day of _______________, 2022 ITEM C. - 1. Page 32 of 32